Owner's manual

7-64 Advanced Programming
7.12 Advanced CPJ +
NOTE Advanced CPJ+ is used for LED encapsulation applications only.
Advanced CPJ+ was designed for LED production to maintain the desired fluid weight per cell within a
prescribed tolerance by adjusting the value of one or more of the following: fluid pressure, shots per cell
and valve on/off times. Advanced CPJ+ automatically adjusts these parameters as required to maintain a
repeatable dot dispense mass.
7.12.1 Enabling Advanced CPJ +
To enable Advanced CPJ+:
1. In the Fluidmove Main Menu, select
Configuration > Configuration Files.
The Edit Configuration Files window opens (Figure 7-51).
2. Make sure that the Run LG Dot Weight Calibration is enabled.
a. Select
Misc Parms in the Configuration Groups section.
b. Click on
Run LG Dot Weight Calibration in the Misc Parms section.
c. Make sure Run LG Dot Weight Calibration is set to ON. If not, click on the down arrow
and select ON from the list.
d. Click
OK.
Figure 7-51 Edit Configuration Files Run LG Dot Weight Calibration