Owner's manual

7-38 Advanced Programming
7.7 RFID
FmXP supports RFID tags located on workpieces containing up to eight individual parts. FmXP reads the
tag prior to dispensing to determine which FmXP program should be loaded and which parts are valid.
After the dispensing process is complete, FmXP writes to the tag to indicate the success/failure status of
each part and to note that dispensing has been completed on the current machine. Prior to using this
feature, RFID must be enabled.
To enable RFID:
1. In the Main Window, select
Configuration > Setup RFID.
The Configuration dialog box ((Figure 7-19) opens.
2. Click the
Enable RFID checkbox to enable RFID.
A checkmark in the box indicates RFID is enabled.
3. Select
Automatic or Manual Mode.
4. Assign a
Flow Control Number.
5. Enter the
Number of Read/Write Retries.
Figure 7-19 RFID Configuration Dialog Box
NOTE Refer to 4.4.13 RFID Setup for a detailed explanation of RFID
configuration options.
7.7.1 RFID Program Association
Each product number and product revision combination must be mapped to an existing FmXP program.
To create, modify or delete an RFID program association:
1. In the Main Window, select
Configuration > Setup RFID.
The Configuration dialog box (Figure 7-19) opens.
2. Click on
Associate.
The RFID Program Association dialog box (Figure 7-20) opens.