Owner's manual
7-26 Advanced Programming
63. Click on Teach.
64. Use the position controls to move the camera crosshairs to the LLHC of the same flip chip.
Use Chip Offset or reticles.
65. Click on
Teach.
66. Use the position controls to move the camera crosshairs to the LRHC of the same flip chip.
Use Chip Offset or reticles.
67. Click on
Teach.
68. Use the position controls to move the camera crosshairs to the URHC of the same flip chip.
Use Chip Offset or reticles.
69. Click on
Teach.
70. Click on
Done.
71. From the
File menu, select Save As and type in M-Pass.fmw to save the file as M-
Pass.fmw
.
Your program should look like this:
1 START PASS: FOR PASS 1
2 FIND SUBSTRATE HEIGHT: (x, y)
3 WEIGHT CONTROL: 30.00,1,([x
1
,y
1
],[x
2
,y
2
])
4 RESET MULTIPASS TIMER:
5 END PASS:
6 START PASS: FOR PASS 2
7 AWAIT MULTIPASS TIMER: 20 seconds(s)
8 WEIGHT CONTROL: 30.000,1,([x
1
,y
1
],[x
2
,y
2
])
9 RESET MULTIPASS TIMER:
10 END PASS:
11 START PASS: FOR PASS 3:
12 AWAIT MULTIPASS TIMER: 20 second(s)
13 WEIGHT CONTROL: 80.000,1,(x
1
,y
1
),(x
2
,y
2
),(x
3
,y
3
),(x
4
,y
4
)
14 END PASS:
15 END:
72. In the Pattern Name text box, select Workpiece to return back to the Workpiece program.
A message box opens indicating that the dispensing head is about to move to the
“Workpiece” origin.
The dispensing head will move after your response.
73. Click on
OK.
74. Place the cursor on
END.
75. Click on the
Process button on the Program Commands toolbar and select Measure
Flow Rate
.
A
Measure Flow Rate command is added to the dispensing program just above END.
76. To set up for placing the pattern
U-pass, click the Pattern button on the Program
Commands toolbar.