Owner's manual

Advanced Programming 7-23
10. Click on Done.
The Edit Window changes and you are asked to select a method for teaching the
first fiducial.
11. Select
Corner Finder.
12. Click on
Next.
13. Teach Fiducial 1 at the same location as the origin.
Make sure that the LLHC of the Quadrant Model is highlighted.
14. Click on
Teach.
15. Test the fiducial or click on
Next.
The Edit Window changes and you are asked to select a method for teaching the
second fiducial.
16. Select
Corner Finder.
17. Click on
Next.
18. Use the position controls to center the camera crosshairs on the URHC of the same flip
chip model.
Make sure that the URHC of the Quadrant Model is highlighted.
19. Click on
Teach.
20. Test the fiducial or click on
Next.
21. Click on
Done.
A message box opens indicating that the dispensing head is about to move to the
Workpiece origin.
The dispensing head will move after your response.
22. Click on
OK.
23. Select
U-pass from the Pattern Name text box.
A message box opens indicating that the dispensing head is about to move to the
U-pass origin.
The dispensing head will move after your response.
24. Click on
OK.
25. From the Program Commands toolbar, click on
Pattern and select Pass Block.
This is the command that allows you to reuse the fiducial and height sense information
for each pass, rather than perform the operation each time.