Owner's manual

Beginning Programming 6-37
30. Set the Line Parameters for Line Type 1 to:
Pre-Move Delay Factor:
0.1
Down Speed:
2
Down Acceleration:
300
Dispense Gap:
0.015
Speed:
(not used for weight control lines)
Shut-off Distance:
0.010
Suckback:
0.000
Dwell:
0.0
Backtrack Gap:
0.050
Backtrack Length:
0.040
Backtrack Speed:
2
Retract Distance:
0.100
Retract Speed:
2
Retract Acceleration:
300
31. Click on Apply.
32. Click on
OK.
33. Click on
File > Save on the menu bar or click on the Save button and enter Lines
for the filename.
Your program should appear similar to the one below.
Figure 6-25 Lines Program Workpiece Pattern
34. In the Programming Window, select Run > Dry Run from the menu bar.
The dispensing head will move after your response.
35. Watch to see the camera traverse the programmed lines. You may observe a difference in
dispensing speed for each line.
If you get an error message that the speed is too slow, re-check your line parameters
and try again. Refer to 6.8.1 Editing Fiducials.
36. In the Programming Window, select
Run > Wet Run from the menu bar.
Watch as the lines are dispensed.
Examine the board for quality and accuracy.