Owner's manual
Beginning Programming 6-25
6.5.5 Editing Dot Parameters
To edit dot parameters:
1. In the Main Window, click on
Teach a Program.
2. In the Programming Window, click on
Edit and select Edit Dot Parameters.
A dialog box may open indicating the type of valve installed on your dispensing system
and which valve, Valve 1 or Valve 2, is currently active.
3. Click on
OK.
The Dot Parameters dialog box opens. See Figure 6-12.
4. To edit the dot parameters, click on the desired tab and type the new value in the
appropriate text box.
5. Click on
Apply.
6. Click
OK when done.
The Dot Parameters dialog box will close.
NOTE When you edit dot parameters, it affects all dots in the program associated with that style.
If you just want to change parameters for one dot in a program, you should define a
new style.
Exercise 6-2: Editing Dot Parameters
1. Perform the Programming Setup routine as described in Section 5 - Programming Basics
and Setup.
2. Load Side 1 of the Tutorial Board.
3. In the Main Window, click on
Teach a Program.
The Programming Window opens.
4. In the Programming Window, select
File > New or click on the Program Wizard icon.
5. Select
One fiducial and Teach Workpiece Origin.
You will now be prompted to teach the workpiece origin and fiducials.
NOTE Refer to Section 5 - Programming Basics and Setup for instructions on program
setup and defining workpiece alignment, origin, and fiducials.
6. Click the
Dispensing Elements button on the Program Commands toolbar.
7. Select
Dot from the Dispensing Elements toolbar.
8. Use the position controls to move the camera crosshairs to the center of the dot in the upper
left-hand corner (ULHC) of the Dots pattern on the Tutorial Board.
9. Click on
Teach.
10. Use the position controls to move the camera crosshairs to the center of the second dot
along the top row of dots.