Owner's manual
System Configuration and Setup 4-129
4.6.2 Production Setup for M-2000, X-1000, S-900, S-800 and D-500
Series Systems
Millennium M-2000, Axiom X-1000, Spectrum S-900, Spectrum S-800, and DispenseMate 500 Series
Dispensing Systems support only Scripted Prompted Setup. Scripted Prompted Setup is similar to the
Non-scripted Prompted Setup procedure, except you have the option of selecting a script file at the
beginning of a Scripted Prompted Setup. The script file customizes the setup procedure to your particular
dispensing system. Any of the setup scripts (.pss files) can be loaded as a Scripted Prompted Setup
routine and can be modified to meet your specific setup routine. Refer to “Setup Scripts Options” in
Online Help for instructions on how to create a setup script.
To perform M-2000/X-100.S-900 Series production setup:
1. In the Main Window, select
Run a Program.
The Production Window (Figure 4-107) opens.
2. In the Production Window, click on Setup > Setup Scripts.
The Run Script Window (Figure 4-107) opens.
3. In the Run Script window, click on
Prompted Setup.
A window opens from which you run your setup script.
4. If you wish to change the script file, click on the
Select File button, select the script (.pss)
file from the directory, and click on
OK.
NOTE The script file can also be selected in the Setup Scripts Options window. Refer
to 4.3.9 Setup Scripts Options for details.
5. Click on
Run to End.
6. Follow the on-screen prompts.
Steps must be performed in the order listed. Completed steps are checked off.
Refer to Online Help for assistance, if necessary.
NOTE If you have a Dual-Action or a Dual-Bracket Dispensing Head, the second
valve must be selected and Scripted Prompted Setup must be run again.