4-124 System Configuration and Setup
4.5.4 Calculate Master Offsets
Calculate Master Offsets identifies and records a safe Z height for dispensing head travel, the XYZ
locations of the Purge and Weigh Stations, and needle/substrate height. It also calibrates the camera
crosshairs to known locations. This basic offsets routine is more manually intensive and potentially less
accurate than the other offset routines.
NOTE Calculate Master Offsets is only available on Century and M-600 Series Dispensing
Systems. It is not available on M-2000, X-1000, Spectrum, or DispenseMate Series
Dispensing Systems.
To perform a Calculate Master Offsets Procedure:
NOTE If your system is equipped with the Dual-Action Dispensing Head, you will be prompted
to repeat some of the setup tasks for Valve 2.
1. Clear the work area of any obstacles that might interfere with dispensing head movement.
2. In the Main Window s
elect Configuration > Machine Offsets > Calculate Master
Offsets.
NOTE If you have an M-600 Series Dispensing System and Calculate Master Offsets
is grayed-out, refer to 4.3.9 Setup Scripts Options to enable it.
The first Teach Window of an uninterrupted series opens (see Figure 4-104). If your
system is equipped with a Dual Action Dispensing Head, Teach Windows for Valve 2
are automatically included in the series.
3. Follow the on-screen prompts. Click on
Help if you have questions.
The Teach Window content and appearance may vary depending on your system
configuration.
4. When you click on
Done in the final Teach Window of the series, you return to the
Main Window.
NOTE If you click on Cancel in any Teach Window, you return to the Main Window
and the new parameters are not saved.