4-122 System Configuration and Setup
4.5.3.2 Setup Fiducials
NOTE The use of this feature requires the use of a special Purge Station lid, Weigh Station lid,
and Needle Sensor sample substrate, which have special marks used as the fiducials.
Contact Nordson ASYMTEK for more information.
To perform Fiducial Assisted Setup:
1. In the Main Window, click on
Configuration > Machine Offsets > Machine Offsets
Parameters
.
The Machine Offset Parameters window (Figure 4-102) opens.
Figure 4-102 Machine Offset Parameters Window
2. Make sure there is a checkmark in the box next to Camera Assisted Script.
3. Click on
Setup Fiducials.
The Machine Fiducial Setup Screen opens. See Figure 4-103.
4. Click on the check box next to the device(s) to be located by fiducials for during the setup
procedure.
The Setup button(s) for the selected device(s) becomes active.
5. Click on
Setup next to the device to open the corresponding Fiducial Setup window and
select the appropriate options. Click on
Help for assistance.
The setup window for the selected device opens.