4-116 System Configuration and Setup
4.5 Machine Setup
Initial machine setup consists of establishing machine offset parameters, using one of the offset routines
listed in Table 4-18. An offset routine is performed by Nordson ASYMTEK after dispensing system
installation and configuration, but you should also perform one when any of the following events occur:
Camera Change or Location Adjustment
Purge Station/Weigh Station Change or Location Adjustment
Valve Change (Not Syringe)
Needle Sensor Change or Location Adjustment
Needle Change
Height Sensor Change or Location Adjustment
Software Upgrade/Reinstallation
The offset routine you choose depends on your dispensing system model and particular application. All
four routines perform the steps required to set up accurate offset parameters that will prevent damage to
the dispensing system or workpieces and help to ensure accurate dispensing performance.
Table 4-18 Machine Offset Routines
Para.
No.
Offset
Routine
Model Description
4.5.1 Valve Offsets All
Allows you to perform one or all of the listed setup tasks
individually.
Access (from Main Window):
Configuration > Machine Offsets > Valve Offsets
Teach a Program > Programming Window Setup Menu
4.5.2
Scripted Valve
Offsets
All
Allows you to customize the Valve Offsets routine to fit your
particular setup needs. You can use one of the standard scripts
included with FmXP, or make one of your own.
Allows you to stop at any point in the setup process, and finish
the process at a later time without having to start from the
beginning as long as you do not exit FmXP.
Access (from Main Window):
Configuration > Machine Offsets > Scripted Valve
Offsets
Teach a Program > Programming Window Setup Menu
4.5.3
Camera-Assisted
Scripted Valve
Offsets
All
The same as Scripted Valve Offsets except uses the camera for
most alignment tasks. Highly accurate. THIS IS THE
PREFERRED METHOD FOR ALL MACHINES.
Access (from Main Window):
Configuration > Machine Offsets > Scripted Valve
Offsets
Teach a Program > Programming Window Setup Menu
4.5.4
Calculate Master
Offsets
Century,
M-600
Slower, more manually intensive, potentially less accurate. NOT
THE PREFERRED METHOD.
Access (from Main Window):
Configuration > Machine Offsets > Calculate Master
Offsets
Teach a Program > Programming Window Setup Menu