Owner's manual
System Configuration and Setup 4-97
Feature Description
Select Station
Click on the arrow to select the dispensing system station you wish to
configure. All of the options on this tab are applied to the selected station.
Board Sensor
The settings for each device will be applied only to the device shown in the
Select Station text box.
Enabled
: If checked, the device is active. No check mark means the device
is inactive.
Input or Output
: Determines the I/O that will be used to communicate with
the device.
Read Delay, Assertion Delay, and Negation Delay
: Determine the amount
of time the system waits for a response from the device before performing
the next task.
Assertion Level
: Determines the On State of the device. A high assertion
level means that when the bit is high, the device is ON. A low assertion
level means that when the bit is low, the device is ON.
Clamp/Lifter
Stop Pin
Vacuum
Figure 4-83 Conveyor Configuration Window (MPC555) – Station I/O Configuration Tab