Owner's manual
System Configuration and Setup 4-89
4.4.9.1 ACL Plus Conveyors
Feature Description
Type
Click on the drop-down arrow to display all available options:
ACL for most Century and Millennium Series Dispensing Systems
MPC555 for X-1000 Series Dispensing Systems
CCACLPlus for Spectrum Series Dispensing Systems
Custom if your system is using a non-Nordson ASYMTEK conveyor
(none) if there is no conveyor installed
Reinitialization
Re-establishes communication between the system computer and the conveyor.
NOTE Reinitialization should be performed after Emergency Stops, after
resetting the conveyor, or if you experience problems operating the
conveyor system.
Configure
Opens a window for customizing conveyor options. See Figure 4-77 (ACL Plus)
or Figure 4-82 (MPC555).
Test I/O
Opens a window identifying all conveyor inputs and outputs. Test an output by
clicking on the button and verifying that the corresponding device responds.
Personality
Parameters
Opens a window displaying conveyor personality parameters. See Figure 4-78.
NOTE This button is not active on X-1000 Series Dispensing Systems.
Automatic Conveyor
Width
Setup - Opens Automatic Conveyor Width Setup Window. See Figure 4-79.
Figure 4-76 Setup Conveyors Window