Owner's manual
4-78 System Configuration and Setup
4.4.6.1 Monitor Scale Cup Overflow Weight (MSOW)
The MSOW was designed to prevent fluid overflow in the scale cup. Fluid accumulation in the scale cup
and fluid overflow can cause severe damage to the scale. MSOW establishes the maximum permissible
weight and can be setup to trigger a warning level and max limit reached prompts.
To activate this feature, click on the box next to
Monitor Scale Cup Overflow Weight in the Scale Setup
Window. A checkmark in the box indicates this feature is activated. If the warning or maximum weight
limit is reached, FmXP displays an error message (Figure 4-68).
Figure 4-68 FmXP Scale Cup Maximum Weight Warning Messages
The beacon can also be configured to indicate the overflow condition. See 4.3.10.6 Beacon Control.
Figure 4-69 Beacon Configuration – Purge/Scale Cup Overflow