Owner's manual
System Configuration and Setup 4-65
Item Description
Enable Floating
Head:
Enables the floating head option.
Floating Head Z
Overtravel:
This value is the distance that the dispensing head will continue to
descend after contacting the substrate. This feature ensures that the
dispensing head makes contact with the substrate even if the substrate
is warped. The floating head absorbs any excess Z overtravel distance.
This feature is used in place of a height sensor.
Figure 4-59 DV/SV Series Valve Settings – Floating Head Tab
NOTE The floating head is available on the DV-7000 model only.