Manual

System Configuration and Setup 4-43
4. Click on the arrow next to the Type box and select the type of Conveyor installed on your
system.
!Most Century and Millennium Series Dispensing Systems use
Automove to communicate
with the Conveyor. The X-1000 Series Dispensing Systems uses
MPC555.
!If you are using a non-Asymtek Conveyor, select Custom. Select (none) for no
Conveyor.
!If your dispensing system is equipped with a dual-lane Conveyor, you need to select the
Conveyor type for Conveyor 2 as well.
5. To select the exact Conveyor style and Conveyor atom to use on your dispensing system,
click on
Configure in the Setup Conveyors dialog box.
!The Setup Configuration - Conveyor dialog box opens. See Figure 4-23.
!Refer to Table 4-11 or Online Help for explanations of each option available in the Setup
Configuration - Conveyor dialog box.
Figure 4-23 Setup Configuration - Conveyor