4-28 System Configuration and Setup
Valve Setup
The Valve Setup process lets you identify and configure the valve(s) installed on your dispensing system.
Valve Setup can be saved and recalled if needed.
To set up Valves:
1. In the Main Window, click on
Configuration.
2. Click on
Setup Valves.
!The Setup Valves dialog box opens. See Figure 4-15.
Figure 4-15 Setup Valves
3. If the type of valve installed on your dispensing system is not automatically highlighted in the
Active Configuration box, use the mouse to select Valve 1 from the list.
!Consult the valve manual included with your dispensing system for help identifying the
type of valve installed on your dispensing system, if necessary. Available valves are listed
in Table 4-6.
Table 4-6 Asymtek Valves
DP-Series DV-Series DJ-Series
DP-2000 DV-6000 DJ-2100
DP-3000 DV-7000 DJ-2200
DV-8000 DJ-9000