Prompted Setup
Prompted Setup is a user-prompted routine to ensure proper offset parameters for the camera, needle,
height sensor, and purge/scale stations. Prompted Setup should be performed:
Prior to all production runs
After a valve has been removed or reinstalled
After a new needle has been placed on the valve assembly
After moving or focusing the camera
After moving or replacing the height sensor probe assembly
Anytime you are experiencing inaccurate dispensing
Part of Prompted Setup includes the Initial Setup procedure (whichever one is selected) as well as other
system preparation tasks. Refer to “Machine Offsets” in the System Configuration and Setup section for
instructions on selecting an initial setup procedure.
" NOTE The Century and M-600 Series Dispensing Systems support the original Prompted
Setup routine, as well as Scripted Prompted Setup. M-2000 and X-1000 Series
Dispensing Systems support only Scripted Prompted Setup.
If you have a Dual-Action or a Dual-Bracket Dispensing Head, it is recommended
that you use the Scripted Prompted Setup described later in this section.
To perform the original Prompted Setup Procedure:
1. Select
Setup Scripts Options from the Configuration Menu.
!The dialog box shown in Figure 8-2 opens.
Figure 8-2 Setup Scripts Options