Advanced Programming 7-45
Total Number of Dots Control Mode
In the Total Number of Dots Control Mode, the valve will dispense a set number of dots for a
particular line.
Total # of Dots – This value determines the total number of dots to be dispensed along the
length of the line.
No Dispensing Control Mode
In the No Dispensing Control Mode, the valve is turned off along the line; generally used in continuous
path methods.
Break Start Point - When used in No Dispensing Control Mode, the Break Start Point is
used as a rounding distance tolerance value to compensate for the offset as the Dispensing
Head turns at the beginning of the line segment where no dispensing occurs (in a continuous
path pattern). See Figure 7-27.
Dispensed Line
No Dispense Line
Turning Radius
Break Start
Dispensed Line
No Dispense Line
Turning Radius
Break Start
Figure 7-27 No Dispensing Control Mode - Break Start Point
Break End Point -When used in No Dispensing Control Mode, the Break End Point is used
as a rounding distance tolerance value to compensate for the offset as the Dispensing Head
turns at the end of the line segment where no dispensing occurs (in a continuous path pattern).
See Figure 7-28.
Dispensed Line
No Dispense Line
Turning Radius
Break End
Dispensed Line
No Dispense Line
Turning Radius
Break End
Figure 7-28 No Dispensing Control Mode - Break End Point
" NOTE For additional information on “Jet on the Fly” technology, contact the Asymtek
Application Engineering Group.