Manual

Advanced Programming 7-39
Creating a Table of Valve Speeds
To create a table of valve speeds:
1. To access the VVS Flowrate screen, click on
Measure Flow Rate on the Process toolbar in
the Programming Window.
! The screen shown in Figure 7-20 will open.
Figure 7-20 Variable Valve Speed Flowrate
" NOTE Valve Speed (%) is a list of the currently programmed valve speeds for each
valve (Valve 1 and Valve 2). The percentage value of each valve speed is a
percentage of the maximum valve speed setup in the Valve Settings dialog box.
2. Click on
New to open the Edit Flowrate Setup for Valve Speed dialog box in which you can
establish a new valve speed and related parameters.
! The screen shown in Figure 7-21 will open.
Figure 7-21 Edit Flowrate Setup for Valve Speed