Manual

Advanced Programming 7-17
12. Use the Position Controls to center the camera crosshairs on the LLHC of the first flip chip
model in the top row of flip chip models.
! Teach the origin exactly at the corner of the flip chip model. You do not use Chip Offset
until you are programming the lines.
13. Click on
Teach.
14. Click on
Done.
! You are now asked to select a method for teaching the fiducial.
15. Select
Corner Finder.
16. Click on
Next.
17. Teach Fid 1 of the pattern Lfill at the same location as the origin.
! Make sure that the LLHC of the Quadrant Model in the area below the video display is
highlighted. If it is not, click on it to highlight it.
18. Click on
Teach.
19. Test Fid 1 or click on
Next.
! The Teach Window closes and the Edit Pattern Skip Info dialog box opens.
20. Select
Skip Pattern If Mark Not Found.
21. Click on
Teach Skip Mark.
! A Teach Window opens asking you to select the method for teaching your skip mark.
22. Select
Model Finder.
23. Click on
Next.
! Use the Position Controls to center the camera crosshairs on the dot slightly above and to
the left of where you taught the origin and fiducial.
24. Click on
Teach.
25. Test the skip mark or click on
Next.
! The Teach Window closes and you return to the Edit Pattern Skip Info dialog box.
26. Click on OK.
27. Click on the
Pattern button on the Program Commands toolbar.