Manual

Beginning Programming 6-29
Retract Speed
This is the speed of the Dispensing Head while moving the Retract Distance. The units are in
inches/second. Typically, 2 in/sec is sufficient.
Retract Acceleration
This is the parameter that controls how fast the Dispensing Head comes up to the Retract Speed. You
may need to set this high for small dispensing moves. The units are inches/second
2
. Typically, 300
in/sec
2
is sufficient.
Jetted Line Parameters
Jetted lines are those dispensed with a DispenseJet valve. Each line is made up of a series of dots. “Jet
on the Fly” is a process of dispensing a line of dots without stopping at each dot position. This feature
can be activated by adding standard line commands to the program. The settings for the specific lines can
then be modified or adjusted by editing the line parameters. For more information, see “Jet on the Fly” in
the Advanced Programming section.
Editing Line Parameters
1. In the Main Window, click on Teach a Program.
2. In the Programming Window, click on
Edit and select Edit Line Parameters.
!A dialog box opens indicating the type of valve installed on your dispensing system and
which valve, Valve 1 or Valve 2, is currently active.
3. Click on
OK.
!The Line Parameters dialog box opens. See Figure 6-13.
4. To edit the line parameters, click on the desired tab and type the new value in the appropriate
text box.
5. Click on
Apply.
6. Click on
OK when done.
!The Line Parameters dialog box will close.
" NOTE When you edit line style parameters, it affects all lines in the program associated
with that style. If you just want to change parameters for one line in a program,