17. For an approximate 30 mil dot, set the Dot Parameters for Type 1 to:
Settling Time: 0
Down Speed: 2 in/sec
Down Acceleration: 300 in/sec2
Valve-On Time: 0.070 sec
Dispense Gap: 0.015 in
Number of Shots: 1
Dwell Time: 0.030 sec
Retract Distance: 0.250 in
Retract Speed: 3 in/sec
Retract Acceleration: 300 in/sec2
Suckback: 0.000
18. Move the cursor to
Type 2 in the Dot Parameters dialog box.
19. Set the Dot Parameter Valve-On Time to 0.250 sec, and Dwell Time to 0.050 sec. Set all the
other parameters for Type 2 to the same settings established for Type 1.
!This will adjust the Valve-On Time and Dwell Time for Type 2 dots.
20. Click on
Apply.
21. Click on
OK.
22. Select
File>Save or click on the Save icon and enter Dots for the filename.
!Your program should appear similar to the one in Figure 6-11. Your XY coordinates
may differ.
Dots
Workpiece
DOT: 1, (1.704, 10,064)
2 DOT: 1, (2.691, 10,064)
3 DOT: 1, (3,439, 10,064)
4 DOT: 1, (4.306, 10,064)
5 DOT: 1, (5,785, 10,064)
6 DOT: 1, (6.195, 10,064)
7 DOT: 2 (1.704, 5.341)
8 DOT: 2, (2.691, 5,341)
9 DOT: 2, (3,439, 5.341)
10 DOT: 2, (4.306, 5.341)
11 DOT: 2, (5,785, 5.341)
12 DOT: 2, (6.195, 5.341)
13 END:
1
Dots
Workpiece
Dots
Workpiece
DOT: 1, (1.704, 10,064)
2 DOT: 1, (2.691, 10,064)
3 DOT: 1, (3,439, 10,064)
4 DOT: 1, (4.306, 10,064)
5 DOT: 1, (5,785, 10,064)
6 DOT: 1, (6.195, 10,064)
7 DOT: 2 (1.704, 5.341)
8 DOT: 2, (2.691, 5,341)
9 DOT: 2, (3,439, 5.341)
10 DOT: 2, (4.306, 5.341)
11 DOT: 2, (5,785, 5.341)
12 DOT: 2, (6.195, 5.341)
13 END:
1 DOT: 1, (1.704, 10,064)
2 DOT: 1, (2.691, 10,064)
3 DOT: 1, (3,439, 10,064)
4 DOT: 1, (4.306, 10,064)
5 DOT: 1, (5,785, 10,064)
6 DOT: 1, (6.195, 10,064)
7 DOT: 2 (1.704, 5.341)
8 DOT: 2, (2.691, 5,341)
9 DOT: 2, (3,439, 5.341)
10 DOT: 2, (4.306, 5.341)
11 DOT: 2, (5,785, 5.341)
12 DOT: 2, (6.195, 5.341)
13 END:
1