6-8 Beginning Programming
Process Commands
When you click on the Process button, a drop-down menu opens containing the available process
commands. When you select a process command, it is inserted into your dispensing program at the cursor
position. Process commands are described in Table 6-1.
Table 6-1 Process Commands
Command Description
Find Substrate Height Determines workpiece height.
Purge Inserts a purge command into a program.
Measure Flow Rate Inserts a Measure Flow Rate command into a program.
Create Procedure Opens dialog box for creating a new procedures.
Call Procedure Opens dialog box for inserting a Procedure into a program.
Send Dispenser Inserts a Send to Dispenser command into the currently
loaded program.
Begin Continuous Inserts a Begin Continuous command into a program. Only
Line commands can be used between a Begin Continuous
and End Continuous instruction.
End Continuous Inserts an End Continuous command into a program. Only
Line commands can be used between a Begin Continuous
and End Continuous instruction.
Change Outputs Selecting this option opens a dialog box in which you can
access all outputs for the Dispenser and the Conveyor. You
can select an output and determine which state to change it
to. The command is inserted into the dispensing program at
the selected location.
If Input Inserts an If Input statement into the dispensing program.
This allows you to specify a particular action based on a
particular input condition.
If System Variable Inserts an If System Variable into the dispensing program.
This allows you to specify a particular action based on a
particular system condition.
Begin Gather Used as a diagnostic tool, mostly by Asymtek Engineers.
Used in conjunction with End Gather.
End Gather Used as a diagnostic tool, mostly by Asymtek Engineers.
Used in conjunction with Begin Gather.
Set Active Valve If your dispensing system is equipped with a Dual Action
Dispensing Head, this feature defines which valve is affected
by the process commands.
Refill Valve Refills the DP Series Dispensing Valve.
PMAC Frame Rotation Available in future releases.
Abort Program Aborts the currently running program.