5. Click on the Flow Rate Parameters tab. See Figure 5-8.
" NOTE If Variable Valve Speed is enabled, the tab will display a "Valve Speeds" column
and "New" and "Remove" buttons. "Enable Flow Rate Maintenance" will not be
available. Refer to “Variable Valve Speed” in the Advanced Programming
section for instructions on enabling Variable Valve Speed.
Figure 5-8 Fluid Manager - Flow Rate Parameters
6. Click on Enable Flow Rate Maintenance to activate Flow Rate Maintenance and select the
desired options. Flow Rate Maintenance options are described in Table 5-2.
" NOTE When a Flow Rate Calibration executes, the specified number of flow rate
calibrations will be performed. Once they are complete, a dialog box opens
indicating which valve was used, which fluid file was used, what bias was used,
and what the flow rate was for each calibration conducted.
If the calculated flow rates are out of valid flow rate range, an error message is
issued. The operator must adjust the valve speed and perform the Flow Rate
Calibration again until the flow rate calculations fall within the specified range.