Programming Basics and Setup 5-13
3. Enter the fluid name in the Fluid Name textbox.
4. Select the purge parameters that best fit your application and fluid.
!Be sure to consider fluid viscosity and throughput.
!Purge Parameter options are described in Table 5-1.
Table 5-1 Purge Parameter Options
Command Description
Vacuum Shutoff
Delay
The time (in milliseconds) set for the Purge Station vacuum to turn off after
the valve shuts off. If zero is entered in the Vacuum Shutoff Delay, the
Purge Station vacuum shuts off simultaneously with the valve.
Vacuum Pre-
Shutoff Time
The time (in milliseconds) set for the Purge Station vacuum to turn off
before the valve shuts off. If zero is entered in the Vacuum Shutoff Delay,
the Purge Station vacuum shuts off simultaneously with the valve.
Enable Purge
Maintenance
Enables purging during production runs. If Purge Maintenance is not
activated, a purge will NOT be performed during the production run.
On Timer
The valve will purge according to the time value (in seconds) entered in
the On Timer text box. Purge timers are reset each time the Run
Production window is opened, or, if in the conveyorized mode, when the
operator clicks on Go.
On Run Count
The valve will purge after it has completed the number of runs entered in
the On Run Count text box.
Purge Duration
Determines the number of seconds that the valve will turn on during a
purge procedure.