System Configuration and Setup 4-65
Scripted Valve Offsets
The Scripted Valve Offsets (SVO) procedure allows you to customize the Valve Offsets routine to fit
your particular setup needs. You can use one of the standard scripts included with FmNT, or make one of
your own. SVO also allows you to stop at any point in the setup process, and finish the process at a later
time without having to start from the beginning. Refer to the Online Help for more information about
creating your own Scripted Valve Offsets procedure.
To perform a Scripted Valve Offsets Procedure:
1. Make sure the work area is clear of any obstacles so the Dispensing Head does not collide
with anything when it moves.
2. In the Main Window, select
Configuration.
3. Click on
Machine Offsets.
4. Select
Scripted Valve Offsets from the cascading menu.
"NOTE If Scripted Valve Offsets is grayed-out, refer to “Machine Offsets” in this
section for instructions on selecting an initial setup procedure.
5. Click on
Run to End.
6. Follow all on-screen prompts.
"NOTE The setup procedure will vary depending on your particular setup script.
!You will be prompted to determine a safe Z height, teach Purge and Scale Station
locations, calculate the Needle-To-Height Sensor Z Offset, calculate the Needle-To-
Camera XY Offset and calculate the Camera-To-Height Sensor XY Offset. See
“Performing a Valve Offsets Procedure” in this section for detailed instructions on how to
perform each procedure.
!Refer to the Online Help for assistance.
"NOTE If your dispensing system is equipped with the Dual-Action Dispensing Head,
perform this procedure twice, once for
Valve 1 and once for Valve 2.