Instruction Manual

Setup and Configuration 6-23
Changing Offsets Mode
Changing Offsets Mode refers to changing from one Initial Setup routine to another. For example, follow
the procedure below to change from Calculate Master Offsets to Valve Offsets.
To change offsets mode:
1. In the Main Window, click on
Configuration.
2. Select
Machine Offsets from the Configuration menu.
3. Select
Machine Offsets Parameters from the drop-down menu.
> The Machine Offsets Parameters dialog box opens. See Figure 6-1.
4. In the
Machine Offsets Mode section of the dialog box, click on the setup procedure you
wish to execute.
> There are three available options:
Scripted Valve Offsets, Valve Offsets and Calculate
Master Offsets
.
5. Notice the
Machine Offsets Parameters section at the bottom of the dialog box. The
available options change depending on the
Offsets Mode selected.
?NOTE To perform a Camera-Assisted Scripted Valve Offsets, select Scripted Valve
Offsets
under Machine Offsets Mode, then click on Camera Assisted Script
under Machine Offsets Parameters. To perform a Fiducial Assisted Setup
procedure, click on Setup Fiducials and consult the Online Help.
?NOTE The ability to use the Fiducial Assisted Setup procedure requires the use of a
special Purge Station lid, Weigh Station lid, and Needle Sensor Sample Substrate
which have special marks used as the fiducials. Contact Asymtek for more
information.
6. Click on
OK.
> You are prompted to restart FmNT.
7. Click on
Yes.