Instruction Manual

Setup and Configuration 6-21
Scripted Valve Offsets
Scripted Valve Offsets allows you to customize the machine offsets routine to fit your specific
requirements. You can use one of the setup scripts included with FmNT, or create a custom script of your
own. SVO also allows you to stop at any point in the setup process, and finish the process at a later time
without having to start from the beginning. Refer to the Online Help for more information about creating
your own Scripted Valve Offsets procedure.
Definitely perform a Scripted Valve Offsets if any of the following events occur:
initial system setup (re-installation of dispensing system)
re-initialization or re-installation of system software
software update
valve change (not syringe)
camera change or location adjustment
service station (Purge, Weigh Stations) change or location adjustment
Needle Sensor change or location adjustment
Height Sensor change or location adjustment
Changing from one of the other offsets routine
To perform a Scripted Valve Offsets procedure:
1. In the Main Window, click on
Configuration.
2. Click on
Machine Offsets on the Configuration menu.
3. Select
Scripted Valve Offsets from the drop-down menu.
?NOTE If Scripted Valve Offsets is greyed-out, refer to “Changing Offsets Mode” later
in this section of the manual, then return here.
4. Click on
Run to End.
5. Follow all on-screen prompts.
> Refer to the Online Help for assistance.
?NOTE If your dispensing system is equipped with the Dual-Action Dispensing Head,
perform this procedure twice, once for
Valve 1 and once for Valve 2.