Instruction Manual
Advanced Programming 9-17
45. Enter 30 mg in the Total Weight text box and select Line Style 1.
46. Use the Position Controls to move the dispensing head to the ULHC of the first flip chip
model in the second row of flips chip models.
> Use Chip Offset or reticles.
47. Click on
Teach.
48. Use the Position Controls to move the dispensing head to the URHC of the same flip chip.
> Use Chip Offset or reticles.
49. Click on
Teach.
50. Click on
Done.
51. From the Program Commands toolbar, click on
Time.
52. Select Reset Multipass Timer.
> This will start a new timer.
53. Place the cursor on the last
END PASS (for Pass 3) and click on Time in the Program
Commands toolbar.
54. Select
Await Multipass Timer.
55. Type in
20 seconds and click on OK.
56. From the Program Commands toolbar, click on
Dispensing Elements.
57. Click on
Weight Control Lines.
58. Enter
80 mg in the Total Weight text box and select Line Style 1.
> This is the total weight to be dispensed at all the locations where this pattern will be
dispensed. In this case, three U-shaped lines around three flip chip models.
59. Use the Position Controls to move the dispensing head to the ULHC of the first flip chip
model in the second row.
> Use Chip Offset or reticles.
60. Click on
Teach.
61. Use the Position Controls to move the dispensing head to the LLHC of the same flip chip.
> Use Chip Offset or reticles.
62. Click on
Teach.
63. Use the Position Controls to move the dispensing head to the LRHC of the same flip chip.
> Use Chip Offset or reticles.