Beginning Programming 8-13
Suckback
At the end of dispensing a line or a dot, the valve is reversed for the Suckback period to remove any
material from the tip of the needle. The Suckback value should be set according to fluid viscosity.
Generally, 10 ms (0.010 sec) is sufficient.
Mid-Move 1 and Mid-Move 2
These parameters are advanced dot parameters used for special applications and testing. For more
information, contact Asymtek Application Engineering.
On Vector Mode/Off Vector Mode
These parameters are advanced dot parameters used for special applications and testing. For more
information, contact Asymtek Application Engineering.
Post Dwell
Post Dwell is the amount of time in seconds that the dispensing head remains in the XY position after
retracting in the Z-axis (see Dwell above). This parameter is available for use in Zfast Mode only and
should be used for fluids with a tendency to string. When used, the total dwell time is the sum of both
Dwell and Post Dwell.
4. Click on
OK to close the Edit Dot Parameters dialog box and return to the Programming
Window.