Instruction Manual

2-2 Installation
Setting up the Dispensing System for FmNT Installation
CAUTION! Please review the Safety section of the Operations Manual for your particular
dispensing system before proceeding.
Before you begin the installation procedure, make certain that your dispensing system is operational by
following the checks below.
?NOTE Reference the dispensing system Operations Manual for the location of
indicated components or options.
1. Make certain that the dispensing system is ON by looking for the following indications.
> If a beacon is present, it should be ON and yellow or green. If the beacon is red, close the
dispensing system doors, hood or window, or press
Reset on the Dispenser and
Conveyor Control panels, if
Reset is present.
> If a beacon is present, but not ON, or if there is no change after you turn the Main Power
switch or press the
Start button, make certain that the Main Circuit Breaker is ON, and
that the system is plugged into an electrical outlet. If the system is not plugged in, consult
a service technician to plug in the system. Make sure that the system is not in an
emergency stop state by checking the
EMO buttons. Twist them clockwise and try
starting the system again.
> If no beacon is present, make sure that the Main Power switch is ON. If an Interlock key
is present, make sure that it is ON (l).
2. Close the dispensing system doors, hood or window, or clear the light curtain area.
3. Make sure that the Main Air is set to a minimum 70 psi.
> Refer to the dispensing system Operations Manual for the location of all components,
and instructions for making air pressure adjustments.