User Manual
Setup and Configuration 6-43
19. Click on Next.
> A dialog box opens asking if you intend to install a new syringe. If you
answer “Yes”, proceed to the next step. If you answer “No”, skip to Step 27.
20. Fill in all of the requested fluid information.
> Consult the documentation that is packaged with the fluid for Thaw Time
Thaw TimeThaw Time
Thaw Time and Lot
LotLot
Lot
Number
NumberNumber
Number information.
21. If your system is equipped with a low fluid sensor, activate the Enable Low Fluid Check
Enable Low Fluid CheckEnable Low Fluid Check
Enable Low Fluid Check
feature.
> Boards After Low Fluid Sense
Boards After Low Fluid SenseBoards After Low Fluid Sense
Boards After Low Fluid Sense is the estimated number of boards that can completed
before the run is paused and the syringe is changed. Consult the On-line Help
for more complete information.
22. Click on OK.
The dispensing head will move after your response.
> The dispensing head moves to the front center of the dispensing area for
syringe installation.
23. Change the syringe.
> Refer to the manual specific to your valve for syringe replacement
instructions.
24. Click on Next.
The dispensing head will move after your response.
25. The dispensing head moves to the Purge Station and prepares for a Flow Rate
Calibration.
26. Follow the on-screen prompts.
This concludes the tutorial on Prompted Setup.