User Manual
Setup and Configuration 6-31
29. Click on Done.
> A new Teach Window opens asking you to select the method for teaching the
Purge Station location.
> Teach 1 Center Point
Teach 1 Center PointTeach 1 Center Point
Teach 1 Center Point is used to teach the location of an object that has an easily
identifiable center, like the Tactile Sensor and the Purge Station, for example.
> Teach 3 Circumference Points
Teach 3 Circumference PointsTeach 3 Circumference Points
Teach 3 Circumference Points is used to teach the location of an object that does not
have an easily identifiable center, like the Weigh Station, for example.
> Center location
Center locationCenter location
Center location is the current X,Y,Z coordinates for the Purge Station.
> Needle to height sense Z offset
Needle to height sense Z offset Needle to height sense Z offset
Needle to height sense Z offset is a positive or negative number, which determines
how deep the needle descends into the purge boot. The number is relative to
the height sense taken after teaching the center location. The height sense is
taken on the Purge Station lid, so a positive offset number means that the
needle will stop that much above the Purge Station lid. A negative number
means that the needle will descend that much deeper into the purge boot.
30. Select the method you wish to use.
31. Click on Next.
32. Use the Position Controls to center the camera crosshairs on the center of the purge
boot.
> This provides FmNT with the X,Y coordinates for the Purge Station location.
33. Click on Teach.
> The dispensing head moves to the side of the Purge Station and asks you to
teach a location on top of the Purge Station lid for a height sense
measurement. This provides FmNT with the Z coordinate for the Purge
Station location, which is used in conjunction with the Needle to height sense Z
Needle to height sense ZNeedle to height sense Z
Needle to height sense Z
offset
offsetoffset
offset to determine how far into the purge boot the needle will descend.
34. Use the Position Controls to center the camera crosshairs on a location on top of the
Purge Station lid for a height sense measurement.
35. Click on Teach.
> The dispensing head performs a height sense in the defined location, then
lowers the needle tip into the purge boot.
> Check the depth of the needle tip and change the Needle to height sense Z offset
Needle to height sense Z offset Needle to height sense Z offset
Needle to height sense Z offset as
required.
36. Click on Done.
> A new Teach Window opens asking you to select a method for teaching the
Weigh Station location. Teach 3 Circumference Points
Teach 3 Circumference PointsTeach 3 Circumference Points
Teach 3 Circumference Points is the default selection. This is
recommended because the Weigh Station opening is large and does not have
an easily definable center.
37. Select the method you wish to use.
38. Click on Next.
39. Use the Position Controls to center the camera crosshairs on a point on the
circumference of the opening on the Weigh Station lid.