User Manual
6-28 Setup and Configuration
44. Click on Run next to 6. Calculate the camera-to-Height Sensor XY offset
6. Calculate the camera-to-Height Sensor XY offset6. Calculate the camera-to-Height Sensor XY offset
6. Calculate the camera-to-Height Sensor XY offset.
The dispensing head will move after your response.
> A Teach Window opens.
45. Choose an easily identifiable mark on the sample substrate, such as a dot or a line
intersection, and use the Position Controls to center the Height Sensor probe tip on
the selected mark.
46. Click on Teach.
47. Use the Position Controls to center the camera crosshairs over the same selected
mark, if necessary.
48. Click on Teach.
49. Click on Done to accept the results.
> The Teach Window closes and you return to the Setup dialog box. Notice that
the box next to number 6 now has an X in it to indicate that Step 6 has been
completed.
?NOTE If your dispensing system is equipped with a dual action dispensing head,
you must also perform a complete Valve Offsets for the second valve.
50. Click on Done.