User Manual
Setup and Configuration 6-25
6. Click on Run next to 1. Teach Safe Z
1. Teach Safe Z1. Teach Safe Z
1. Teach Safe Z.
> A Teach Window opens.
7. Activate the Z-axis controls.
8. Raise or lower the dispensing head to a Safe Z Height.
> Safe Z Height is determined by choosing a height that ensures that the needle
or any other part of the dispensing head does not come in contact with any
obstacles while traveling anywhere around the dispensing area.
9. Click on Teach.
10. Click on Done.
> The Teach Window closes and you return to the Setup dialog box. Notice that
the box next to number 1 now has an X in it to indicate that Step 1 has been
completed.
11. Click on Run next to 2. Teach Purge Location
2. Teach Purge Location2. Teach Purge Location
2. Teach Purge Location.
The dispensing head will move after your response.
> The dispensing head Finds Home, then moves to the Purge Station location. A
Teach Window opens.
12. Use the Position Controls to align the needle tip to the purge boot opening at the
Purge Station.
13. Activate the Z-axis controls and lower the needle tip into the purge boot.
14. Click on Teach.
15. Click on Done.
> The Teach Window closes and you return to the Setup dialog box. Notice that
the box next to number 2 now has an X in it to indicate that Step 2 has been
completed.
16. Click on Run next to 3. Teach Scale Location
3. Teach Scale Location3. Teach Scale Location
3. Teach Scale Location.
The dispensing head will move after your response.
> The dispensing head moves to the Weigh Station location. A Teach Window
opens.
17. Use the Position Controls to align the needle tip to the opening in the Weigh Station
lid.
18. Activate the Z-axis controls and lower the needle tip into the opening.
19. Click on Teach.
20. Click on Done.
> The Teach Window closes and you return to the Setup dialog box. Notice that
the box next to number 3 now has an X in it to indicate that Step 3 has been
completed.