6-2 Setup and Configuration
System Configuration
The System Configuration procedure should be performed by
trained service personnel only.
After installing your dispensing system, or after installing FmNT, it is necessary to identify
certain options included on the system platform. These options include, but are not limited
to, the following:
· Needle Sensor
· Valve(s)
· Low Fluid Sensor(s)
· Height Sensor
· Scale
· Vision System
· Conveyor(s)
· Heaters
?NOTE Generally, System Configuration is performed at the Asymtek factory prior
to shipping, and you may never have to perform this procedure. Contact
Asymtek Technical Support for more information.
?NOTE Advanced service engineers or Asymtek Field Service engineers may
perform the entire System Configuration procedure by editing the
Configuration Files through the Configuration menu.
Estimated time to complete: 20 minutes
To configure the dispensing system:
1. Start FmNT.
> Refer to “Starting FmNT” in Section 3–Tour of Fluidmove for help, if
necessary.
2. In the Main Window, click on Configuration.
3. Select Needle Setup
Needle SetupNeedle Setup
Needle Setup from the Configuration menu.
4. Select Setup Parameters
Setup ParametersSetup Parameters
Setup Parameters from the drop-down menu.
> The Needle Setup Parameters dialog box opens. See Figure 6-1.