Heater Control for Windows 4-3
Each loop has a dialog box which shows its settings under the Main tab.
Figure 4-2 shows the Main tab dialog box and the other tabs to access more dialog
boxes. In the Main dialog box, you set the temperature with Set Point. The Output
Value is the percentage of the total capacity of the heater being used to achieve or
maintain the Set Point. Auto Mode regulates the loop temperature automatically.
Manual Mode disables the automatic temperature controller and allows you to
regulate loop temperature using the Output Value.
?NOTE Operating in Manual Mode is not recommended. Output Value can
not exceed Heat Output Limit. See the Output tab.