Advanced Programming 9-9
> A message box opens indicating the calculated line speed.
47. Click on OK.
48. From the Program Commands toolbar, click on Time and select Reset Multipass Timer
Reset Multipass TimerReset Multipass Timer
Reset Multipass Timer.
> This will start the timer after the first line is dispensed.
49. Place the cursor on the second
END PASS and click on Time in the Program
Commands toolbar.
50. Select Await Multipass Timer
Await Multipass TimerAwait Multipass Timer
Await Multipass Timer.
> The Await Multipass Timer instruction dialog box opens.
51. Type in 30 seconds.
> The system will wait for 30 seconds before beginning the next run.
> Set the timer according to how long your fluid takes to underfill the flip chip
model.
52. Click on OK.
53. From the Program Commands toolbar, click on Dispensing Element.
54. Select Weight-Control Lines.
55. Enter 30 mg in the Total Weight
Total WeightTotal Weight
Total Weight text box and select Line Style 1.
56. Use the Position Controls to move the dispensing head to the ULHC of the first
flip chip in the ULHC of Pattern 1.
> Use Chip Offset or reticles.
57. Click on Teach.
58. Use the Position Controls to move the dispensing head to the LLHC of the same
flip chip.
> Use Chip Offset or reticles.
59. Click on Teach.
60. Use the Position Controls to move the dispensing head to the LRHC of the same
flip chip.
> Use Chip Offset or reticles.
61. Click on Teach.
62. Click on Done.
> A message box opens indicating the calculated line speed.
63. Click on OK.