User Manual

8-16 Beginning Programming
13. For an approximate 30 mil dot, set the Dot Parameters for Type 1 to:
Settling Time: 0
Down Speed: 2 in/sec
Down Acceleration: 300 in/sec
2
Valve-On Time: 0.070 sec
Dispense Gap: 0.015 in
Number of Shots: 1
Dwell Time: 0.030 sec
Retract Distance: 0.250 in
Retract Speed: 3 in/sec
Retract Acceleration: 300 in/sec
2
Suckback: 0.000
14. Move the cursor to Type 2 in the Dot Parameters dialog box.
15. Set the Dot Parameter Valve-On Time to 0.250 sec, and Dwell Time to 0.050 sec.
Set all the other parameters Type 2 to the same settings established for Type 1.
> This will adjust the Valve-On Time and Dwell Time for Type 2 dots.
16. Click on Apply.
17. Click on OK.
18. Select Dry Run
Dry RunDry Run
Dry Run from the Run
RunRun
Run menu.
> Watch to see the camera locate the position of the dots.
The dispensing head will move after your response.
19. Select Wet Run
Wet RunWet Run
Wet Run from the Run
RunRun
Run menu.
> Watch to see the dots dispensed.
> Examine the board, you should notice a difference in the size of the Type 1
and Type 2 dots.
This concludes the tutorial on Dots.