User Manual

Beginning Programming 8-11
25. In the Programming Window, select Edit Line Parameters
Edit Line ParametersEdit Line Parameters
Edit Line Parameters from the Edit
EditEdit
Edit menu to open
the Line Parameters dialog box.
26. Set the Line Parameters for Line Type 1 to:
Pre-Move Delay Factor: 0.1
Down Speed: 2
Down Acceleration: 300
Dispense Gap: 0.015
Speed: (not used for weight control lines)
Shut-off Distance: 0.010
Suckback: 0.000
Dwell: 0.0
Backtrack Gap: 0.050
Backtrack Length: 0.040
Backtrack Speed: 2
Retract Distance: 0.100
Retract Speed: 2
Retract Acceleration: 300
27. Click on Apply.
28. Click on OK.
29. In the Programming Window, select Dry Run
Dry RunDry Run
Dry Run from the Run
RunRun
Run menu.
> Watch to see the camera transverse the programmed lines. You may observe a
difference in dispensing speed for each line.
The dispensing head will move after your response.
If you get an error message that the speed is too slow, re-check your line
parameters and try again. Refer to Editing Lines earlier in this chapter.
30. In the Programming Window, select Wet Run
Wet RunWet Run
Wet Run from the Run
RunRun
Run menu.
> Watch as the lines are dispensed.
> Examine the board for quality and accuracy.
This concludes the tutorial on Weight Control Lines.