Programming Basics 7-11
23. Click on the Run Time tab.
> Check for location tolerances means that FmNT will check the found
location of the fiducial and compare it to the location where it expected to
find it. If the difference between the two locations is greater than the Location
Tolerance, FmNT will consider the fiducial to be Not Found. This ensures
that an incorrect fiducial or other feature is not considered to be a correct
fiducial, and prevents dispensing on parts that are too far away from their
expected locations.
24. Click on the Image tab.
> Read the
TIP section on Gain below.
25. Click on the Model Finder tab.
26. When you are satisfied with the fiducial, click on Teach.
27. Test the fiducial by clicking on Find Fid.
> The Test Results indicate if the fiducial was found or not, its found
coordinates, how sure the system is that it has found the correct fiducial, and
how long it took to locate the fiducial.
28. Click on Next to accept the results.
> You are now asked to select the method for Fid 2.
29. Select Model Finder
Model FinderModel Finder
Model Finder.
30. Click on Next.
TIP
Gain
The Gain controls the way digital values are assigned to the
analog signal from the camera. Lower Gain values will
increase the contrast of the image and may help to
differentiate the fiducial from the background. However, a
low Gain value may also amplify “noise” in the image.
Therefore, it is recommended that you first adjust the light
level, then adjust the Gain only if necessary.
The default value of the Gain is 255.