User guide

Operation 17
Figure 4-1 Easy Coat Flow Meter Test
b. Use the Gun On and Gun Off buttons to start and stop dispensing (
Figure 4-2).
c. Use the Begin Measurement and End Measurement buttons to start and end a flow
reading. When you click the End Measurement button, the flow data is logged into the
database.
d. Observe the digital readout in the Meter Reading window to verify that the software is
incrementing the signal count from the flow meter.
"NOTE Ensure that the coating material is flowing out of the fluid applicator while the software is
incrementing the flow meter signals. If there is no flow, see Section
6 - Troubleshooting.
Figure 4-2 Flow Meter Utility Screen