Manual

Installation 2-3
9. Install the protective tubing over the sensor cables.
10. Route the fiber optic lines to the Fan Width Enclosure.
11. Use a tie-wrap to secure the fiber optic cables and tubing to the Drain Pan Mounting Plate.
See Figure 2-1.
12. Using the M4 screws provided and the 2.5-mm hex key, attach the Drain Pan Clamps to the
Drain Pan Mounting Plate. Do not tighten the clamps at this time.
13. Place the Drain pan in the Drain Pan Bracket.
14. Attach the Drain Tube to the outlet on the bottom of the Drain Pan.
15. Decide the best route for the Drain Tube, and route the Drain Tube to the Reservoir at the
back of the dispensing system.
16. Attach the Drain Tube to the Reservoir.
17. Secure the Drain Tube to the dispensing system or some other stable fixture to prevent the
tubing from coming detached from the Drain Pan when the Reservoir is emptied.
?NOTE When emptying the Reservoir, unscrew the cap and leave it attached to the Drain
Tube.
18. Place the Baffle in the Drain Pan.
19. Secure the Baffle and the Drain Pan by using the 2.5-mm hex key to tighten the Drain Pan
Clamps.