Manual

Configuration and Characterization 4-33
To add Periodic Timers:
1. Click
Configure > Production from the ECXP Edit Screen.
The Configure Production dialog box opens.
2. Click on the
Add Periodic Task button.
A new sequentially numbered periodic timer will be added to the list.
To set Periodic Timers:
1. Click on
Configure > Production from the ECXP Edit Screen.
The Production Configuration dialog box opens. See Figure 4-29.
Figure 4-29 Production Configuration Window
2. Click on the periodic timer you wish to set from the list.
Selected timers are highlighted.
3. Enter a description (optional).
4. Select the desired mode from the drop down list in the Value field.
5. Enter the desired period in the Value field.
If you chose Time, enter the desired number of seconds. If you chose Count, enter the
desired number of products.
To turn off timers:
1. Click on
Configure > Production from the ECXP Edit Screen.
The Production Configuration dialog box opens. See Figure 4-29.
2. Click on the periodic timer you wish to turn off.
3. Set the mode to
Disabled.
NOTE If the periodic procedure is not found when the periodic timer expires, the Event Monitor
displays the warning message "Periodic (or Periodic1, Periodic2…) should have been
run, but none found.” Production continues.