Manual
4-14 Configuration and Characterization
4.6.2 Configuring a Fixture on Systems Equipped with a Camera
To configure a fixture on systems equipped with a camera:
NOTE If necessary, install the fluid dispensing applicator. The applicator must be installed
before teaching the X-coordinate and Y-coordinate.
1. Press
[F4] to open the camera viewing window.
2. Resize the ECXP Operator and Edit Screens so that the camera window cross-hairs are
visible at the left side of the screen, behind the Operator and Edit Screens.
3. Select the
Genie Camera as the tool (Figure 4-14).
The camera may or may not be selected as the pointer also.
Figure 4-14 Active Tool - Genie Camera
4. Click on Configure > Fixtures from the ECXP Edit Screen.
The
Fixture Configuration dialog box (Figure 4-15) opens.
Figure 4-15 ECXP Fixture Configuration
5. Click on the tab for the fixture you are configuring.
There will be a separate tab for each fixture configured in ECXP. The default fixture is
Fixture A.