Manual

B-14 Appendix B - Instruction Properties
SC-400 Control
Description: Sets the properties for the SC-400.
Properties:
Property Description
Duration (seconds)
Value in seconds for the time the SC-400 is open for either position-based or
time-based mode.
Mode
Sets the SC-400 to either position-based or time-based mode.
Period (seconds)
Value in seconds for the total time of one cycle when in time-based mode.
Spacing (mm)
Value in mm for the spacing between shots when in position-based mode.
Tool
Default = Tool displayed in Current Tool Selector when the instruction is
created. Tool to use for this instruction. Click on List button to select a
different tool.
Send ACL to Conveyor
Description: Sends an ACL command to the Conveyor Controller.
Properties:
Property Description
ACL String
String to send to A201 Conveyor Controller.
Send ACL to Robot
Description: Sends an ACL command to the Robot Controller.
Properties:
Property Description
ACL String
String to send to A201 Robot Controller.
Set Acceleration
Description: Sets the acceleration for move and coating instructions. Overrides the ECW.INI file settings.
Properties:
Property Description
Acceleration
Value in inches/sec/sec or millimeters/sec/sec.