Manual

Programming 5-23
10. For each fiducial instruction, choose the desired action if the fiducial is not found.
See Figure 5-24 and Table 5-1.
Figure 5-24 Fiducial Not Found
Table 5-1 Fiducial Not Found Options
Instruction Action
Manual Find
1. If “Manual Find” is chosen, Figure 5-25 will appear and the
program will pause.
2. Using the jog keys, center the crosshairs over the fiducial.
3. Press the
button to manually locate the fiducial.
Abort Program
If “Abort Program” is chosen, the dispensing program will end
and production will be stopped.
Skip Program
If “Skip Program” is chosen, the dispensing program will end for
the current product but production will continue.
Skip Pattern
If “Skip Pattern” is chosen, the current pattern will be skipped
and the rest of the patterns will continue for the current product.
11. Repeat the above instructions for the remainder of the fiducials.
Figure 5-25 Manual Fiducial Find
NOTE Abort Program, Skip Program and Skip Pattern may also be chosen during a
manual fiducial operation.