Manual

Programming 5-19
4. To change coordinates, move the tool tip to the pattern starting point and click the
Teach Field button. Teaching the first set of coordinates activates the second set,
if required. See 5.9.5 Teaching Coordinates with the Camera to teach instruction
coordinates with the camera.
5. Complete the Property section and click on
Save .
NOTE Highlight the pattern to see the pattern properties. Highlight the instruction to
see the instruction properties. Refer to Appendix B for a description of all
instruction properties.
Figure 5-18 Pattern and Instruction Properties
5.9.5 Teaching Coordinates with the Camera
The SL-940E/SL-941E coating systems both have an optional teach camera or an optional fiducial find
camera. The teach camera provides an onscreen display of the area to be coated to eliminate guesswork
as to where coating will be dispensed. The fiducial find camera provides all the features of the teach
camera, as well as closed loop feedback to correct translation and rotation of boards located in a carrier or
directly on the conveyor.
5.9.5.1 Teach Camera
The teach camera teaches coordinates for existing instructions. Insert the coating instructions for the
appropriate tools and then update the coordinates with the camera.
To teach coordinates using the teach camera:
1. Make sure the pattern name is selected and click on the desired instruction.
Note the position of the arrows (->) next to the coordinates in the instruction properties.
The arrows indicate which coordinate will be taught when you click the
Teach button
in the camera window.
2. Press [
F4] to open the camera window.
3. Move the camera over the position that you want to teach.
The reticle in the camera window represents the characterized pass width for the active
tool.
Instruction
Properties
Pattern