User guide
Configuration and Characterization 4-21
4.12.2 Dual Applicators (Only One Fits in Needle Finder)
1. Click on Configure > Needle Finder Setup to open the Needle Finder Setup dialog box
(Figure 4-16).
2. Set the Tool Offset for the applicator that doesn't fit into the needle finder (large applicator)
to a nominal value.
3. Click on the
Teach Relative button on the Tool Configuration dialog box to set the offset for
the small applicator, using the large applicator as the reference tool. See 4.4.1.1 Dual
Applicators/Needle Finder.
4. Teach the laser X-beam and Y-beam locations with the small applicator.
5. Use either tool to configure the fixture. See 4.6 Fixture Configuration
4.12.3 Tolerances
Click on the Tolerance button to set the out-of-position tolerances used by ECXP to generate an error and
call the procedure named in the Find Needle or Check Needle error procedure properties.