Upgrade Kit Owner manual
4 Upgrading the DP-3000
Installing the Motor
Refer to Figure 2-2 and Figure 2-3 to locate parts.
To install the new motor:
1. With the swinging bracket open, slide the new motor into the back of the DP-3000.
2. Rotate the motor mount disc so that the bolt circle lines up with the bolt circle on the motor.
3. Install the three screws onto the motor mount, and use the 2.5-mm hex key to tighten them.
" NOTE It is recommended that you use Loctite Removable Threadlocker #242 when replacing
these screws to prevent them from loosening when the pump vibrates.
4. Replace the motor gear onto the motor shaft.
! Align the hole in the motor gear with the flat part of the motor shaft.
5. Insert the set screw into the motor gear.
6. Align the motor gear so that it is exactly the same height as the feed screw gear.
CAUTION! It is important that the gears are properly aligned for the pump to function
correctly. Gears that are not aligned to the same height may shear, causing
damage to the pump.
7. Using a 1/16-inch hex key, tighten the motor gear set screw.
8. Connect the red motor cable connector to the red socket on the valve control PCA. See
Figure 2-2.
! Make sure that all PCA connections are tight.
9. Replace the main cover, and secure it with the three screws.
10. Replace the gear cover, and secure it with the three screws.
11. Reinstall the DP-3000 on the dispensing system.
! Refer to the DP-3000 Owner’s Manual for instructions.